|
|
 |
BC785DGV - APCO 25 Digital Capable Scanner Featuring
1,000 Channels
Continuous Band Coverage includes Aircraft & 800
MHz bands including deluxe scanner headphone
For maximum scanning satisfaction, also order Scancat
scanner control software version 8.50
Factory new in box
- not refurbished or repaired
The
BC785DGV is
sold out and discontinued at Communications Electronics. Place your
order now for the new
BC796DGV scanner.
Order on-line today.
Looking for handheld scanner
like the BC785DGV, check out the Bearcat
BC250DGV
Due to Canadian Government restrictions, we are currently unable to
export the BC250D or BC785D to Canada.
For more information on this please refer to the following
documents: RSS-135,
RSS-215 & IPC-2-1-04.
For further assistance, telephone or e-mail your regional Industry
Canada Spectrum Management and Telecommunications office.
| SOLD
OUT - Price was $279.95
Replaced
with BC796DGV
price includes $30.00 UPS Ground shipping/handling/insurance per
scanner to a street address in the continental USA excluding Alaska.
Save 50% on shipping/handling and insurance charges when you order
in full case quantities of six units per case.
The GV means "Great Value."
When you buy the Bearcat 785DGV Trunktracker package deal from
Communications Electronics, you get more. With your BC785DGV scanner
you also get a deluxe scanner headphone designed for home or race
track use. Features independent volume controls, 3.5 mm gold right
angle plug and one year limited factory warranty.
For additional ordering &
delivery information click
here
|
|
BC785DGV
|
|
QUANTITY
|
PRICE
EACH
[Includes Shipping]
|
|
1
|
$279.95
|
|
2
|
$278.95
|
|
3
|
$277.95
|
|
4
|
$276.95
|
|
5
|
$275.95
|
|
6-12
|
$274.95
|
|
13-18
|
$272.95
|
|
19-24
|
$270.95
|
|
25+
|
$269.95
|
|
|

To
monitor APCO 25 Digital Systems you must purchase this BCi25D
Digital Card which fits both the BC250D and the BC785D Scanners
$219.95
To have the BCi25D shipped
with your BC785DGV (when not on backorder), add $9 to the shipping
fee.
You save money on shipping when you buy the scanner and digital
card together. If you order the BCi25D separately, shipping will
be $15.
|
|
BCi25D
|
|
QUANTITY
|
PRICE
EACH
|
|
1
|
$219.95
|
|
2
|
$218.95
|
|
3
|
$217.95
|
|
4
|
$216.95
|
|
5
|
$215.95
|
|
6-12
|
$214.95
|
|
13-18
|
$212.95
|
|
19-24
|
$210.95
|
|
25+
|
$209.95
|
|
Click
here for free 100 page BC785D Operations Guide (1.17 MB)
Domestic
warranty service available

United States of America
Factory customer care 1-800-297-1023
Uniden customer care fax 1-800-323-2641
|
Manufactured
in

China |


|
-
Digital Capable - APCO
Project 25 Digital Capable. Not compatible with 9,600 baud APCO
digital control channel with digital voice, AEGIS, ASTRO or ESAS
systems. With the optional BCi25D APCO Project
25 Digital Card installed, you can monitor public safety
organizations who currently use conventional, trunked at 3,600 baud
analog control channel and digital voice and mixed mode APCO Project
25 systems.
-
TrunkTracker III - Search
for and monitor all the groups within a specific trunked system.
Lockout unwanted groups during the search and save other groups
to scan lists. (EDACS, Motorola, E.F. Johnson). Follow
VHF High Band, UHF 800/900 MHz trunked public safety and public
service systems just as if conventional two-way communications were
used.
-
Multi-Track - Track more than
one trunking system at a time. Scan conventional and trunked systems
at the same time.
-
1,000 Channels - Program one
frequency into each channel. You must have at least one channel
programmed to use the scan mode.
-
27 Bands - Includes 27 bands,
with aircraft and 800 MHz.
-
Continuous Band Coverage (25 MHz
TO 1.3 GHz) - Allows coverage from virtually every frequency
from 25 MHz to 1.3 GHz excluding the cellular bands and UHF TV band,
so you can tune into police, fire, weather, ambulance, aircraft,
military, "Ham" radio and much more.
-
10 Banks - 10 banks with 100
channels each are useful for storing similar frequencies to maintain
faster scanning cycles or for storing all the frequencies of a trunked
system.
-
10 Priority Channels - You
can assign one priority channel in each bank. Assigning a priority
channel allows you to keep track of activity on your most important
channel(s) while monitoring other channels for transmissions. You
can also assign trunking priority talk groups. When Priority Scan
is turned On, your scanner checks the priority channel in the banks
you selected every 2 seconds for activity. If a signal is present
on the priority channel, your scanner monitors the channel until
the transmission ends, then resumes normal scanning. You can designate
one channel in each bank as a Priority Channel. By default, the
first channel in each bank is the Priority Channel, but you can
change this setting.
-
Priority Plus Scan - Allows
you to scan only priority channels.
-
Preprogrammed Service Searches
(10) - This feature allows you to toggle through preprogrammed
public safety, news media TV broadcast audio, Amateur (ham) radio,
CB radio, Family Radio Service, special low power, railroad, aircraft,
marine, racing and weather frequencies.
-
Unique Data Skip - Allows
your scanner to skip unwanted data transmissions and reduces birdies.
-
Memory Backup
- If power is disconnected, the frequencies programmed in your scanner
are retained in memory.
-
Direct Channel Access - Jump
directly to any channel without stepping through other channels
or entering menu mode.
-
RF Attenuator
- The BC785D comes with an RF Attenuation feature. If you are near
an unusually strong signal source, the signal may overload the scanner.
The RF Attenuation features works in all modes and attenuates (reduces)
the incoming signal strength to prevent stronger signals from overloading
the scanner.
-
PC Programmable - This feature
allows the user to remotely program and control the scanner using
third party software (available from www.usascan.com).
Optional baud rates include 2400, 4800, 9600 (default) and 19200
operating through the scanner's DB-9 RS-232C port.
-
Turbo Search - Increases
the search speed to 300 steps per second when searching transmission
bands with 5 KHz steps.
-
Turbo Scan - This lightning
fast technology allows you to scan and search nearly 100 channels
or steps per second.
-
Auto Store - The BC785D can
automatically store any found active frequencies into an assigned
bank.
-
CTCSS/DCS - This feature allows
the user to assign analog and digital subaudible tone codes to a
specific frequency in memory. The scanner will also search for unknown
CTCSS and DCS tones.
-
National Weather Radio -
Can be programmed to receive special localized weather warnings
broadcast by NOAA. The scanner is compatible
with warning siren and message transmissions.
-
Specific
Area Message Encoding (S.A.M.E.) weather alert - S.A.M.E. is
NOAA’s coded emergency weather signals that identify a specific
geographic area affected by an emergency. In weather alert with
S.A.M.E. mode, your scanner functions as a county specific severe
weather warning radio. To obtain further information about S.A.M.E.
and FIPS code, visit http://www.nws.noaa.gov/nwr/index.html.
-
FIPS Code
- This feature allows you to input a six-digit
code Federal Information Processing System
(FIPS) code that will designate a localized severe weather
warning. The BC785D can decode the
6-digit FIPS code established by the National Weather Service (NWS).
This FIPS code identifies geographic areas anywhere in the United
States, US territories and US possessions. Programming the FIPS
code is necessary to receive S.A.M.E. alerts about weather occurring
in a particular area. To obtain a FIPS code for your area, call
the National Weather Service toll free at 1-888-697-7263 or visit
http://205.156.54.206/nwr/nwrsame.htm.
-
Dimmer - Allows you to change
the brightness of the display.
-
Enter Lock - Allows you to
lockout the keypad to prevent reprogramming of channels, talkgroups
and tones.
-
Key Beep Option - Allows you
to turn the key beep on or off.
-
Screen Mask - Screen Mask
allows you to limit what appears on the display to the alpha tags
that you have set for a channel along with a few function icons.
Screen Mask removes the frequency, receiving mode tone data and
signal strength bars. This mode is particularly useful in public
safety vehicles where "information overload" is already
a problem. Screen Mask does not work in Search mode.
-
Reverse Mode - This key will
allow you to observe the reverse frequency of the repeater. While
pressing "RVRS", the standard repeater pair frequency
will be displayed.
-
Channel Step Selection - You
can set channel steps, 5 kHz to 100 kHz or Auto, in conventional
mode or chain search mode. The default receive mode should be the
proper mode setting in almost all cases. You may wish to set some
VHF channels for NFM mode, depending on any adjacent channel interference
problems. WFM is typically used for broadcast frequencies such as
TV audio or FM radio.
-
Mute On/Off - Allows you to
manually turn the mute function on or off.
-
Receiving Mode Selection -
You can set the receiving mode, AM or FM in conventional mode or
chain search mode.
-
Duplicate Frequency Alert
- If you enter a frequency which has been stored in another channel,
you will hear a beep and the channel stored displays a duplicate
warning message.
-
2 Line Alpha Display - You
can customize your scanner by storing text tags for easy identification
of banks, channel transmission, trunking talk group ID and more.
Allows for alpha tagging display of channel, bank or search range.
-
Control Channel Only Mode - Allows
the user to automatically trunk certain systems by simply programming
the control channel.
-
Backlit Full-Frequency Display
- Shows the channels being scanned and the frequency entered
into each channel with an easy-to-read backlit display for enhanced
night visibility.
-
Clone Feature - Allows for
cloning of another scanner's programmed frequencies. (The two
scanner's must be connected by a cloning cable for the cloning
process to take place.)
-
Alpha Tagging - Allows the
user to assign an alpha description to each channel, trunking talk
group and bank.
-
Beep Alert - You can set
a Beep Alert on a per-channel basis to alert you when specific frequencies
are active. For example, you may wish to be alerted anytime a mutual
aid fire frequency is active. With beep alert, you will hear three
beeps at the start of each transmission that you have flagged as
such. You will also notice that as you scroll pass the flagged channel(s),
you will hear three beeps.
-
Record Function - Allows the
user to designate a channel to be recorded by an external device.
The user will be able to select between ON and OFF. The default
setting is OFF. An icon will appear in the LCD when a channel has
been assigned the record feature (requires an external recording
device.)
-
VFO Control - Allows the user
to tune through frequencies, channels, alpha characters and more
with the handy VFO tuning knob.
-
Menu-Driven Design - This
function allows advanced programming and control operation through
the easy-to-use menu system.
-
Frequency Delay Selection - A
default delay of 2 seconds is automatically set for each frequency
or talk group A different delay can be set for each programmed channel
so that when scan or search stops on a channel there is a brief
pause before the scanning cycle resumes. To set the delay feature,
enter into the menu mode.
-
Negative Delay Selection
- Setting negative delay periods are useful if you are only interested
in small segments of conversations. For example: If you set a -5
second delay, you will only hear 5 seconds of the conversation and
then the scanner will resume scanning, whether or not the conversation
is finished.
-
Total Channel Control - Allows
the user to program delay, step, mode (adjustable) priority, attenuation
and more on a per-channel basis.
-
Chain search mode - When the
scanner finds an active frequency, the trunk tracking system will
be active. Four frequency
plans apply to the Control Channel Only feature
-
Trunk Search - Search for
and monitor all the groups within a trunked system. Lockout unwanted
groups during the search and save other groups to scan lists.
-
Trunk Lockout - Lockout groups
you don't wish to monitor, (including data groups) from the trunked
system.
-
Trunk Delay - Apply a five
second delay to trunking groups so that both sides of a conversation
can be heard, even if the trunking frequencies change between replies.
-
One Touch Weather - Automatically
scans all national weather channels with a single touch.
-
Turbo Scan - This lightning
fast technology allows you to scan and search nearly 100 channels
or steps per second.
-
Memory Backup - Retains frequencies
entered for more than 3 days without batteries or during a power
failure.
-
Programmable Search - Allows
you to find new frequencies in any of the bands.
-
Manual Channel Access - Go
directly to any channels without stepping through other channels.
SPECIFICATIONS:
| CHANNELS
|
1,000 Channels (100
channels x 10 Banks) |
| BANDS |
27 Bands |
| PREPROGRAMMED SERVICES
|
Service
Search menus are preprogrammed services used across the United
States. Select services from the following: Weather, Public Safety,
news, TV broadcast, Amateur (ham) radio, Marine, Railroad, Aircraft,
CB radio, Family Radio Service. |
| FREQUENCY RANGE
|
25.0000 - 26.9600
MHz (Petroleum Products & Broadcast Pickup)
26.9650 - 27.4050 MHz (CB Radio)
27.4100 - 27.9950 MHz (Business & Forest Products)
28.0000 - 29.6900 MHz (10 Meter Amateur Band)
29.7000 - 49.9900 MHz (VHF Low Band)
50.0000 - 53.9900 MHz (6 Meter Amateur Band)
54.0000 - 71.9500 MHz (VHF TV)
72.0000 - 75.9950 MHz (Intersystem & Astronomy)
76.0000 - 87.9500 MHz (VHF TV)
88.0000 - 107.9000 MHz (FM Broadcast)
108.0000 - 136.9750 MHz (Aircraft Band)
137.0000 - 143.9950 MHz (Military Land Mobile)
144.0000 - 147.9950 MHz (2 Meter Amateur Band)
148.0000 - 161.9950 (VHF High Band - 5 KHz spacing)
162.000-173.9875 MHz (VHF High Band - 12.5
KHz spacing)
174.0000 - 215.9500 MHz (VHF TV)
216.0000 - 224.9950 MHz (1.25 Meter Amateur)
225.0000 - 399.9500 MHz (UHF Aircraft Band)
400.0000 - 405.9875 MHz (UHF Aircraft Band)
406.0000 - 419.9875 MHz (Federal Government Land Mobile)
420.0000 - 449.9875 MHz (70 cm Amateur Band)
450.0000 - 469.9875 MHz (UHF Standard Band)
470.0000 - 512.0000 MHz (Public Service & TV Band)
806.0000 - 823.9875 MHz (Public Service Band)
849.0125 - 868.9875 MHz (Public Service Band)
894.0125 - 956.0000 MHz (Public Service Band)
1240.0000 - 1300.0000 MHz (25 cm Amateur Band) |
| WEATHER FREQUENCY
|
162.4000
- 165.5500 MHz (25 kHz Step) |
| DISPLAY |
Full LCD
(with back light)
(BANK, LIST, SCAN, SEARCH, HOLD, P RI, DLY, L/O, LINE, FREQ, CHAN,
ALPHA, RMT, AUTO, ATT, ALT) |
| CONTROLS/SWITCHES
|
Volume/Squelch Control
with power ON/OFF switch
VFO Rotary Encoder with Pulsh Switch |
| POWER REQUIREMENTS
|
DC 13.8V
(External Power Jack) |
| EXTERNAL JACKS
|
Antenna Jack: BNC
Type
Phone Jack: 3.5 Ø
Record Jack: 3.5 Ø
DC Power Jack: 5.5 Ø
Remote Interface Jack: D-Sub 9-pin |
| INTERNAL SPEAKER
|
8 ohm, 2 watts (56
Ø) |
| SCAN RATE
|
Up to 100 channels
per second |
| MODES |
AM/FM/WFM (adjustable
per channel) |
| STEP SIZES (kHz)
|
5, 7.5, 10, 12.5,
25, 50, 100 |
| SCAN DELAY
|
none, 1,
2, 4, infinite (stay on until Resume is pressed), -2, -5, -10
seconds |
| AUDIO OUTPUT
|
8 Resistance Load
|
| ANTENNA |
50 ohms |
| OPERATING TEMPERATURE
|
-4° F - 140° F
-20° C - 60° C |
| STORAGE TEMPERATURE
|
-22° F - 140° F
-30° C - 60° C |
| SIZE |
7-5/8” Wide x 6-15/16”
Deep x 2-13/16” High
195.0 mm Wide x 177.0 mm Deep x 72.0 mm High |
| WEIGHT |
2.93 pounds
1.33 kg |
| UPC CODE |
0-45799-68888-0
|
| MASTER CARTON QUANTITY
|
6
|
| SINGLE UNIT CARTON DIMENSIONS
|
12-3/4”
Wide x 8-1/2” Deep x 4” High |
|
INCLUDED ACCESSORIES
|
AT248
Telescopic Antenna, AD580U
AC Adapter, PS001
Cigarette Lighter Cord, PS002
DC Cord, MB785D
Mounting Bracket with Screws, OMBC785D
Owner's Manual, TTFREQ
Trunking Frequency Guide Book, ESCAN E-Scanner programming Software
CD-ROM, Screwdriver, HF24RS
Headset, BBFREQ
Betty Bearcat Starter Frequency Guide |
OPTIONAL
ACCESSORIES
| PART
|
DESCRIPTION
|
PRICE
|
| ANTMMBNC
|
Magnetic
Mount Antenna w/ BNC Connector & 12 Feet Cable
|
$29.95 |
| AT002 |
Window
Mount/Suction Cup Antenna w/ BNC Connector & 10 Feet Cable |
$15.95 |
| BCi25D
|
APCO
25 Digital Card |
$239.95
|
| SGFW |
Scancat
Gold for Windows Scanner Control Software |
$99.95 |
| SGFWSE |
Scancat Gold for Windows
Surveillance Edition Software |
$159.95 |
REPLACEMENT
ACCESSORIES
| PART
|
DESCRIPTION
|
PRICE
|
|
AD580U |
AC
Adapter 120VAC to 13.8 VDC @ 700 mA - 18 watts |
$19.95
|
|
ANTMMBNC |
Magnetic
Mount Antenna w/ BNC Connector & 12 Feet Cable
|
$29.95 |
| AT002 |
Window Mount/Suction
Cup Antenna w/ BNC Connector & 10 Feet Cable |
$15.95 |
| AT248 |
Replacement
antenna |
$14.95 |
| BCi25D |
APCO
25 Digital Card |
$239.95
|
| ESCAN |
E-Scanner
Software |
$19.95
|
| HF24RS |
Scanner
Headset |
$29.95
|
| MB785D |
Mounting
Bracket |
$19.95 |
| OMBC785D |
Owners Manual
for BC785D scanner |
$14.95 |
| PS001 |
Cigarette
Lighter DC Cord |
$14.95 |
| PS002 |
Vehicle Power Cord
DC Power Cord (Hardwire) |
$14.95 |
| TTFREQ |
Trunking
Frequency Guide Book |
$9.95 |
Click here for information on understanding scanning.
You must be 100%
satisfied with your Bearcat scanner when you order from CEI. All Bearcat
scanners purchased directly from CEI are sold for your evaluation
and testing for 61 days before you decide to keep it (excluding CEI
E-values).
The installation,
possession, or use of any radio receiver in a motor vehicle may be
prohibited, regulated, or require a permit in certain states, cities
and/or local jurisdiction. Your local law enforcement officers should
be able to provide this information regarding the laws in your community.
Click
here for more information on scanning legally.
Features, specifications,
availability of optional accessories or database services are all
subject to change without notice. The Smartscan 900 telephone number
Uniden National Frequency Database feature and service has been discontinued.
|
 |